How do you tell if the blower motor is bad or the resistor?
Symptoms of a bad heater blower motor resistor
- Fan does not work at all, so no air comes out of the vents.
- Fan only works on some speeds and not others.
- Fan only works on the highest speed.
- Fan runs all the time and can’t be controlled with the fan switch.
- You see smoke coming out of the vents.
What are the signs of a bad blower motor?
5 Signs Your Blower Motor Needs to Be Replaced
- Weak Airflow from the Vents. This is usually the first indication that you may have a faulty blower motor.
- No Airflow at All.
- Unusually High Energy Bills.
- Strange Sounds.
- Overheating.
How much does it cost to replace a blower motor in a truck?
In most instances this repair is on the relatively inexpensive side. A new blower motor will run between $50 and $100. Most blower motors sit in the dash underneath the glove box, and are accessible for replacement. Installation will run in the range of $80–$100.
What does heater blower resistor do?
The blower motor resistor in your car is the part that is responsible for pushing air through the vents when using the air conditioner or heater. The blower motor resistor is constantly put under stress which can cause it to eventually fail.
What happens when a blower motor resistor goes bad?
If the resistor shorts or fails, it may cause the blower motor to remain stuck on one fan speed. The heating and air conditioning systems may still function at one speed, however the resistor will have to be replaced in order for full functionality to be restored.
What happens when blower motor relay goes bad?
If the blower motor relay develops any sort of problem that hinders its ability to properly limit and distribute power, it may cause the blower motor fuse to blow. Any sort of electrical spikes or excessive current from a bad relay will blow the fuse and cut power in order to protect the system.
What can cause a blower motor to stop working?
In a situation where the motor doesn’t work on any speed, the most likely causes are: a blown power supply fuse, a bad motor ground connection, bad motor speed control module or a failed motor. On all systems, a failed blower motor is least likely. Start by checking the blower fuse and HVAC controller fuse.
What does a bad blower motor sound like?
A defective blower motor will make a continuous sound noticeable by the passengers in the vehicle. It can manifest as a knocking, whirring, clunking, vibrating, squealing, or whining noise that persists until the blower motor is replaced.
Can you drive with a bad blower motor?
A bad heater blower motor will not affect the safety of your car, with the possible exception of you not being able to clear the windshield of snow, ice, or condensation if the defrosters don’t work. But you won’t be comfortable inside your car, especially during the cold of winter and the heat of summer.
Is there a fuse for the blower motor?
The blower motor is powered by a fuse-like device called a relay. If your heater or air conditioner does not blow air through the vents, this could indicate that the blower motor fuse has probably blown. While replacement is easy, the exact location of your blower motor fuse may vary from vehicle to vehicle.