Why is my Vokera boiler flashing green?
Flashing green lights When the green light is constantly on it means the flame is working, but a flashing green light could be due to a faulty hot water sensor or because it is in standby. A reset may be enough but if not you may need to get in touch to arrange an engineer to diagnose the issue.
How do you reset a Vokera compact He boiler?
To reset the appliance, make sure the gas supply is on to the appliance. Turn the mode selector switch to the OFF position for a few seconds and then turn it back to its previous position. If the red LED stays on or is illuminated after a few seconds call an engineer. service your appliance.
How do you reset Vokera?
To reset your Vokera boiler, move the mode selector switch to the ‘OFF/RESET’ position and then move it back to either ‘hot water only’ or ‘heating and hot water’. Should this reboot get your boiler working again then you’ll know because there will be a constant green light.
What pressure should my Vokera boiler be at?
between 1 and 1.5 bar
The pressure gauge shows the current pressure of the system, the gauge should be set between 1 and 1.5 bar. When the appliance is operating the gauge may rise or fall slightly, this is quite normal. The minimum permissible level for the safe and efficient operation of the appliance is 0.5 bar.
What does flashing green light on hive mean?
Flashing Fast Green = Hub is trying to connect to the internet. Flashing Slow Green = Hub is trying to connect to the Hive servers or is in upgrade mode. Wait for 20 minutes and refresh your Hive app.
How do you reset a Vokera compact 25a?
What does ao1 mean on Vokera boiler?
ignition fault
A01 is an ignition fault on Vokera boilers. If you’ve lost pressure (likely a different cause), it’s likely you have a leak in your heating system. The leak could cause the A01 fault code by way of “dry fire”. I.e. the boiler recognises it’s not safe to ignite.
What does a red light mean on a Vokera boiler?
The red light on the display panel indicates a fault with your boiler. The way in which the light is flashing will help indicate the problem. For example, on a Vokera Compact you might see an A01 fault code with a red flashing light, which indicates there has been a failure in the ignition sequence.
Why is my Vokera boiler losing pressure?
Pressure loss may be caused from a leak in the pressure relief valve, an issue in the expansion vessel, air in your system, or a leak in the heating pipework itself. 99% of the time, a boiler losing pressure is a leak.
How long do Vokera boilers last?
In terms of reliability, Vokera boilers are thought to be around middle of the line, and are pretty reliable for around the first five years after purchase. Longer term, Vokera boilers can run into difficulties, mainly due to their cheaper, Italian-manufactured components.
What does a green light mean on a vokera boiler?
A constant green light on your Vokèra boiler is a sign that the flame within the boiler is working, and that’s what you want to see. Should the green light start flashing, that’s when there could be an issue to worry about:
Why are the lights on my vokera boiler flashing?
The following could be the case whether the lights are solid, or flashing. The water pressure in the system is too high or low (the boiler will usually lockout below 0.6 bar and above 3 bar) Your Vokera boiler is stuck in service mode (most likely if it’s brand new, or you’ve just had a service from an engineer)
How tall is a compact 24 SE vokera?
1.6 DIMENSIONS 1.7 CLEARANCES REQUIRED ABOVE 150 mm BELOW 150 mm LEFT SIDE 12 mm RIGHT SIDE 12 mm FRONT 600 mm Compact 24 SE HEIGHT 715 mm WIDTH 405 mm DEPTH 248 mm 1.8 FROST PROTECTION SYSTEM
What is frost protection on compact 24 vokera boiler?
The Compact SE is equipped with a built-in frost protection system, this enables the boiler to over-ride the time controls – even if switched off – and operate the burner and/or pump, should the temperature drop below 50C for the main and for the DHW line.