Can ULC S102 test?

The CAN/ULC-S102 test, when conducted in triplicate, reports Flame Spread (FS) and Smoke Development (SD) values for the specific product or assembly evaluated. A light and photoelectric cell record smoke obscuration during the test to validate the material’s smoke development characteristics.

Can ULC S102 flame spread ratings?

The National Building Code goes on to say in Article 3.1. 5.11. (2) to say that even if you achieve a flame spread rating of 25 or less when tested in accordance with CAN/ULC S102 you still have to protect the material from the interior of the building with a thermal barrier as defined in that Article.

What is ASTM E84 test?

ASTM E 84. Standard test method for surface burning characteristics of of building materials. The flame spread Index and Smoke Developed Index values obtained by the ASTM E 84. test are used by code officials and regulatory agencies in the acceptance of interior finish. materials for various applications.

What is CAN ULC S102?

The CAN/ULC-S102 Surface Burning Characteristics of Building Materials and Assemblies test is the Canadian standard for the relative surface burning characteristics of interior finish materials, products, and assemblies used in building construction.

Can ULC S102 07?

TEST PROCEDURE The method, designated as CAN/ULC-S102-07, “Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies”, is designed to determine the relative surface burning characteristics of materials under specific test conditions.

What is ULC S102?

TEST PROCEDURE The method, designated as CAN/ULC-S102-2018, “Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies “, is designed to determine the relative surface burning characteristics of materials under specific test conditions.

What is class 3 flame rating?

What is a Class C or Class 3 fire rating? A Class C or Class 3 fire rating has a flame spread rating between 76 and 200. This rating incorporates building materials like plywood, fiberboard, and hardboard siding panels. It also includes any of the faster burning whole woods.

What NFPA 255?

NFPA 255: Standard Method of Test of Surface Burning Characteristics of Building Materials is referenced by the NFPA 101®: Life Safety Code® and building codes as the test procedure to be used for establishing the values associated with a material’s flame spread and smoke density indexes, when used as interior wall and …

What does can ULC stand for?

Underwriters Laboratories of Canada
Underwriters Laboratories of Canada (ULC)

Is the ASTM E84 the same as the CAN / ULC S102?

If the results achieved from the ASTM E84 and the CAN/ULC S102 were the same or if there was a direct correlation between ASTM E84 and CAN/ULC S102, then an argument could be proposed which would recognize ASTM E84. However, the results are completely different and there is no correlation between the two standards.

What do you need to know about ASTM E84?

What is ASTM E84? ASTM E84 is an American standard test method for surface burning characteristics of Building Materials (equivalent to the Canadian standard CAN/ULC-S102). A 10-minute test in a Steiner Tunnel allows to determine the Flame Spread and Smoke Density index.

What is the ULC standard for surface burning?

ULC CAN-S102.2 – STANDARD METHOD OF TEST FOR SURFACE BURNING CHARACTERISTICS OF FLOORING, FLOOR COVERINGS, AND MISCELLANEOUS MATERIALS AND ASSEMBLIES. Published by ULC on June 1, 2018. This Standard is applicable to the finished surface or covering of a floor extending to a maximum depth of 65 mm.

Is the Steiner tunnel test the same as UL 723?

I n the U.S., the Steiner Tunnel test is typically designated as ASTM E84 (or UL 723), while in Canada it is widely known as CAN/ULC-S102. Both tunnels are identical dimensionally and are run under nominally the same operating conditions.

Previous post Do worlds strongest man take steroids?
Next post Wie nimmt man an einer Miss Wahl teil?